Ametek ROTRON Regenerative Blower DR523K72 037210 230/460 VAC 3 hp Three Phase
6 in Stock, Ready to Ship.
PRODUCT DETAILS
Manufacturer | Ametek |
Brand | ROTRON |
Product Type | Regenerative Blower |
Model | DR523K72 |
Part # | 037210 |
Series | Domestic Regenerative (DR) |
Horse Power | 3.0 HP |
Motor Type | TEFC |
Input Voltage | 230/460 VAC |
Phase | 3 PH |
Frequency | 50/60 Hz |
Current Rating | 8.9/4.5 A |
Inlet/Outlet Diameter | 1.5" |
Max Pressure | 158 IWG |
Max Air Flow | 84 SCFM |
Weight | 112 LBS |
Package Dimensions | 21" x 16" x 16" |
The DR523 family of blowers are classified as "high-pressure" blowers. With a max pressure rating of 158 IWG, this blower is used often in aquariums and ponds to oxygenate water as it can bubble water up to 10 feet deep. It's commonly used in many different industrial applications that need lower flow with medium pressure.
See the Ametek ROTRON DR523K72 Product Bulletin / Catalog Page / Datasheet Here.
DR523 Service Guide & Parts Manual Here
The Ametek Rotron DR 523 series regenerative direct drive blower is designed for commercial spas, as well as hotels/motels, health clubs, and condominiums. These applications require a continuous duty blower with low noise levels (compliant with OSHA standards). The Ametek Rotron DR 523 series is manufactured in the USA. It is compliant with ISO 9001 requirements as well as with CE Marking standards (Declaration of Conformity available upon request). The blower housing is composed of cast aluminum with cast iron threaded flanges, and the motor is UL and CSA approved, as it contains permanently sealed ball bearings and Class B rated thermal protection.
Additional options of the Rotron DR regenerative blower include: (a) corrosion resistant surface treatments and sealing options; (b) remote drive-motorless-models; and (c) slip-on or face flanges for application-specific needs.
The maximum operating temperature for the motor should not exceed 140°C (Class F rated motors), and the maximum temperature of the outlet air for the blower should not exceed 140°C (this includes air temperature rise plus inlet temperature). The maximum pressure and suction/vacuum figures seen in the air flow x pressure performance curves (see datasheet, page 2) are based on a 40°C inlet and ambient temperature.